PROCEDURE TO
RUN H F O PURIFIER
1.
CHECK GEAR OIL LEVEL.
2.
OPEN SUCTION
&DISCHARGE V/V
3.
OPEN 5
HV-165HV-11&PUMP INTERCONNECTION V/V ON DISCHARGE SIDE FOR PURIFIER NO 1,
4.
CHECK EPC 30 PRO GRAMME
5.
MAKE SURE PROGRAMME
SWITCH IS IN STOP POSITION.
6.
CHECK MARST 1 CONTROL
UNIT
7.
CHANGE OVER SWITCH FROM
OFF TO STANDBY POSITION.
8.
WAIT 120 SEC(until 000
appear)
9.
START PURIFIER.
10. START OIL FEED PUMP.
11. OPEN INLET
&OUTLET V/V OF OIL HEATER , DON’T FORGET TO CHECK AGAIN WHEATHER IT
SHOWS SETTING TEMPERATURE.
12. TURN EPC 30 UNIT SWITCH
TO POSITION RUN.
13. (WHITE LAMP OPERATION &YELLOW LAMP DISCHARGE WILL SHOW)
14. WHEN DISCHARGE REG LAMP GOES OFF , START MARST 1 UNIT FROM
STANDBY TO ON POSITION.
PROGRAMME TO STOP PURIFIER
- TURN SWITCH TO STOP POSITION ON EPC 30 UNIT.
- WHITE OPERATION LAMP WILL OFF; YELLOW DISCHARGE LAMP WILL START FLASHING.
- SWITCH OFF MARST 1 UNIT (WHITE LAMP WILL GOES OFF).
- AFTER 20 SEC ,YELLOW DISCHARGE LAMP BECOME STANDBY LIGHT.
- RETURN MARST 1 UNIT TO STANDBY POSITION.
- PURIFIER WILL STOP AUTOMATICALLY WITHIN 3 MIN.
- MAKE SURE PURIFIER COME TO STANDSTILL.
DRAIN THE BOWL
- MAKE SURE TO RELEASE THE BRAKE IF IT WAS ON.
- START THE PURIFIER MANUALLY ON THE MOTOR STARTER &RUN FOR A MINUTE IN ORDER TO EMPTY THE BOWL.DON’T USE THE PROGRAMME SWITCH.
- OFF EPC 30 UNIT.